Rectifiers and Accessories (3-4 WEEK LEAD TIME)



Power Supplies - Rectifiers

Kocour Rectifiers for Hull Cell Testing are expressly designed units which utilize filtered circuits capable of continuously producing minimum AC ripple. This filtered current output is essential for testing many plating baths.

Kocour Rectifiers are strongly recommended for Hull Cell tests because results are misleading when single phase unfiltered current is used.

Product Features:

  • Silicon rectifiers
  • Filtered DC current source
  • Output 0-12 volts DC with less than 3% ripple
  • Continuous control from 0 to maximum
  • Calibrated digital voltmeter and ammeter accurate within 2%
  • Primary and secondary fuse protection
  • Models available in 115V/60Hz or 220V/50Hz

SKU Details



Sku Images SKU Description Model Applications Price
Rectifier, 5 Amp Digital 115 Volt (050070D)
View details
Output 0-9 volts DC at 5 amps with less than 3% ripple and continuous control from 0 to maximum. Full wave center tap and rectification. Calibrated digital voltmeter and ammeter accurate within 2% of full scale. Primary and secondary fuse protection. 5D, Input 115V, 60Hz A filtered DC current source for laboratory and Hull Cell Tests.
   
Rectifier, 15 Amp Digital 115 Volt (050071D)
View details
Output 0-12 volts DC at 15 amps with less than 3% ripple and continuous control from 0 to maximum. Full wave center tap and rectification. Calibrated digital voltmeter and ammeter accurate within 2% of full scale. Primary and secondary fuse protection. 15D, Input 115V, 60Hz A highly filtered and very efficient DC current source for laboratory and Hull Cell Tests.
   
Rectifier, 25 Amp Digital 115 Volt (050073D)
View details
Output 0-12 volts DC at 25 amps with powerstat voltage control. Complete thermal and fuse protections and continuous voltage control from 0 to maximum. 25D, Input 115V, 60Hz
   
Test Leads (050074)
View details
Test leads for all Kocour rectifiers.
   
Rectifier, 5 Amp Digital 220 Volt (050076D)
View details
Output 0-9 volts DC at 5 amps with less than 3% ripple and continuous control from 0 to maximum. Full wave center tap and rectification. Calibrated digital voltmeter and ammeter accurate within 2% of full scale. Primary and secondary fuse protection. 5D, Input 220V, 50Hz A filtered DC current source for laboratory and Hull Cell Tests.
Rectifier, 15 Amp Digital 220 Volt (050077D)
View details
Output 0-12 volts DC at 15 amps with less than 3% ripple and continuous control from 0 to maximum. Full wave center tap and rectification. Calibrated digital voltmeter and ammeter accurate within 2% of full scale. Primary and secondary fuse protection. 15D, Input 220V, 50Hz A highly filtered and very efficient DC current source for laboratory and Hull Cell Tests.
Rectifier, 25 Amp Digital 220 Volt (050079D)
View details
Output 0-12 volts DC at 25 amps with powerstat voltage control. Complete thermal and fuse protections and continuous voltage control from 0 to maximum. 25D, Input 220V, 50Hz